Pack Release
Pack Release
When a pack is opened, the OR staff can quickly verify that the conditions for sterilization were achieved and that the instruments and utensils are safe to use in surgical procedures.
Overblik
Indicators for monitoring the specific sterilization parameters of time, temperature and – depending on sterilization method – steam, Formaldehyde, Ethylene Oxide and relative humidity inside the pack.
Product Ranges
Pack Release for Steam
Integrating Indicator (Strip) Steam
Clear blue Pass/Fail results.
Overview

The Getinge Assured MI Steam Migrating Integrator Strips are designed to react to all critical process variables for steam sterilization cycles according to ISO 11140-1, Type 5 Integrating Indicators.
During steam sterilization, the chemical pellet melts and migrates as a blue color along the paper wick. The migration is visible through a window marked FAIL or PASS.
*Not available for sales in the US
Conforms to EN ISO 11140-1 Type 5
Easy interpretation with “PASS” and “FAIL” windows
Assurance to the user that minimum cycle parameters have been achieved inside the pack
Cost effective
Steam sterilizers operating at 134°C for 3 minutes or longer
Compatible with all steam sterilization methods
Technical data
Packaging
Order No | |
Getinge Assured MI Steam Migrating Integrator Strip, L 50.8 mm, 250 pcs per bag | 6005500510 |
Green Tape Steam
Color change from green to black.
Overview

The Getinge Assured Green Tape (Steam) can be used in 121°C gravity sterilizers and 132-135°C pre-vacuum sterilizers.
Stripes turn black after exposure to steam sterilization conditions, thus providing identification of processed items.
* Not available for sales in the USA.
Tape for sterilization packages
Enviromental friendly
Green tape does not contain lead
Two widths, 18 mm and 24 mm
Color change from green to black
Consistent with EN ISO 11140-1, Type 1
Technical data
Packaging
Order No | |
Green Tape 18mm Steam, 48 rolls per box | 6001154902 |
Green Tape 24mm Steam, 36 rolls per box | 6001154903 |
Multicritical Process Variable Indicator Steam
Conforms to EN ISO 11140-1 Type 4.
Overview

The Getinge Assured Multicritical Process Variable Indicator (Steam) is designed to be used in steam sterilizers operating at 132 to 134°C and 121°C. When used as directed, Multicritical Process Variable Indicator (Steam) gives a visible indication that sterilizing parameters (time, temperature and steam) were met according to EN ISO 11140-1.
* Not available for sales in the USA.
Conforms to EN ISO 11140-1 Type 4
Laminated (short) and Unlaminated (long)
Clear color change from white to black
Assurance to the user that minimum cycle parameters have been achieved inside the pack
Can be used as a permanent record
Cost effective
Technical data
Packaging
Order No | |
Multicritical Process Variable indicator, short, L: 101 mm, laminated, 250 pcs per case | 504051700 |
Multicritical Process Variable indicator, long, L: 195 mm, unlaminated, 250 pcs per case | 504051800 |
Emulating Indicator (Strip) Steam
Clear color change from purple to green.
Overview
The OR staff is responsible for maintaining the integrity of the sterile field. Getinge Assured Emulating Indicators (Type 6) are the most advanced chemical indicators for monitoring the specific steam sterilization parameters of time, temperature and steam inside the pack and assures the user that maximum values for all cycle parameters have been achieved.

Our Type 6 indicators have the highest precision available and require a full steam sterilization cycle to change color.
When a pack is opened, your OR staff can quickly verify that the conditions for sterilization were achieved and that the instruments and utensils are safe to use in surgical procedures.
* Not available for sales in the USA.
Clear color change from purple to green
Superior diagnostic ink technology
Lead free and no toxic heavy metals
Can be used as a permanent record
Consistent with EN ISO 11140-1 Type 6
Cycle specific calibrations – 134°C at 4, 5.3, 7 and 18 mins
Technical data
Packaging
Order No | |
Emulating indicator 4, 4 minutes 134°C, 250 pcs per case | 504051000 |
Emulating indicator 5.3, 5.3 minutes 134°C, 250 pcs per case | 504050800 |
Emulating indicator 7, 7 minutes 134°C, 250 pcs per case | 504050900 |
Emulating indicator 18, 18 minutes 134°C, 250 pcs per case | 504051400 |
Emulating Indicator (Adhesive) Steam
Clear color change from purple to green.
Overview
The OR staff is responsible for maintaining the integrity of the sterile field. Getinge Assured Emulating Indicators (Type 6) are the most advanced chemical indicators for monitoring the specific steam sterilization parameters of time, temperature and steam inside the pack and assures the user that maximum values for all cycle parameters have been achieved.

Our Type 6 indicators have the highest precision available and require a full steam sterilization cycle to change color.
When a pack is opened, your OR staff can quickly verify that the conditions for sterilization were achieved and that the instruments and utensils are safe to use in surgical procedures.
This indicator is also self-adhesive which facilitates record-keeping.
* Not available for sales in the USA.
Self-adhesive for easier handling
Superior diagnostic ink technology
Lead free and no toxic heavy metals
Can be used as a permanent record
Consistent with EN ISO 11140-1 Type 6
Cycle specific calibrations – 134°C at 3.5, 4, 5.3 and 7 mins
Technical data
Packaging
Order No | |
Emulating indicator 3.5 Adhesive, 3.5 minutes 134°C, 250 pcs per case | 504051100 |
Emulating indicator 4 Adhesive, 4 minutes 134°C, 250 pcs per case | 504052600 |
Emulating indicator 5.3 Adhesive, 5.3 minutes 134°C, 250 pcs per case | 504051200 |
Emulating indicator 7 Adhesive, 7 minutes 134°C, 250 pcs per case | 504051300 |
Pack Release for Low Temp
Multicritical Process Variable Indicator (VH2O2)
Clear color change from black to green.
Overview

The Getinge Assured Multicritical Process Variable Indicator (VH2O2) is designed to react to the critical process variables of time, temperature and hydrogen peroxide concentration in vaporized hydrogen peroxide processes.
When exposed to hydrogen peroxide, the diamond symbol changes color from black to green.
*Not available for sales in the US
Conforms to EN ISO 11140-1 Type 4
Clear color change from black to green
Assurance to the user that minimum cycle parameters have been achieved inside the pack
Can be used as a permanent record
Cost effective
Compatible with VH2O2 sterilizers
Technical data
Packaging
Order No | |
Multicritical Process Variable Indicator VH2O2, L 101 mm, 250 pcs per bag | 6005500509 |
Multicritical Process Variable Indicator EO (Ethylene Oxide)
Clear color change from yellow to brown.
Overview
The Getinge Assured Multicritical Process Variable Indicator (Ethylene Oxide) is designed to be used in Ethylene Oxide (EO) gas sterilizers.
When used as directed the indicator gives a visual confirmation that the items being sterilized have been subjected to the parameters of time, temperature, EO concentration and relative humidity according to EN ISO 11140-1, Type 4.
* Not available for sales in the USA.
Assurance to the user that minimum cycle parameters have been achieved inside the load
Can be used as a permanent record
Cost effective
Conforms to EN ISO 11140-1, Type 4
Technical data
Packaging
Order No | |
Multicritical Process Variable Indicator EO (Ethylene Oxide), 250 pcs per bag | 504051600 |
Multicritical Process Variable Indicator Formaldehyde
Clear color change from red to green.
Overview
The Getinge Assured Multicritical Process Variable Indicator (Formaldehyde) is designed to be used in low temperature steam/formaldehyde (LTSF) sterilizers.
When used as directed the indicator gives a visual confirmation that the items being sterilized have been subjected to the following parameters of time, temperature and Formaldehyde concentration according to EN ISO 11140-1, Type 4.
* Not available for sales in the USA.
Assurance to the user that minimum cycle parameters have been achieved inside the load
Can be used as a permanent record
Cost effective
Conforms to EN ISO 11140-1, Type 4
Technical data
Packaging
Order No | |
Multicritical Process Variable Indicator Formaldehyde, 250 pcs per case | 504051900 |
Plasma Indicator
Clear color change from blue to pink.
Overview
The Getinge Assured Plasma Indicator gives visible confirmation that the pack has been exposed to hydrogen peroxide. When exposed to H2O2 sterilization process, the Plasma Indicator will change from blue to a shade of pink.
* Not available for sales in the USA.
Assurance to the user that the pack was exposed to hydrogen peroxide
Can be used as a permanent record
Cost effective
Designed to monitor plasma sterilizers/VHP/Hydrogen Peroxide Sterilizers
Technical data
Packaging
Order No | |
Plasma Indicator, 250 pcs per case | 504052000 |
Tape EO (Ethylene Oxide)
Tape for sterilization packages.
Overview
The Getinge Assured Tape (Ethylene Oxide) is designed for use in ethylene oxide (EO) sterilizers operating at 600 mg/l EO gas, 40-60% Relative Humidity, 54°C for 45 minutes or longer. The word "gas" turns green after exposure to an EO gas sterilization process, thus providing identification of processed items.
* Not available for sales in the USA.
For use in Ethylene Oxide sterilizers
Two widths, 18 mm and 24 mm
Color change from brown to green
EN ISO 11140-1, Type 1
Technical data
Packaging
Order No | |
Tape 18mm Ethylene Oxide, 48 rolls per box | 504053600 |
Tape 24mm Ethylene Oxide, 36 rolls per box | 504053700 |
Pack Release for Dry Heat
Multicritical Process Variable Indicator Dry Heat
Clear color change from green to dark brown/black.
The Getinge Assured Multicritical Process Variable Indicator (Dry Heat)
is designed to be used in dry heat sterilizers.
When used as directed, the indicator gives visible confirmation that the goods were sufficiently exposed to dry heat sterilization conditions as specified by EN ISO 11140-1, Type 4.
* Not available for sales in the USA.
Assurance to the user that minimum cycle parameters have been achieved inside the load
Can be used as a permanent record
Cost effective
Conforms to EN ISO 11140-1, Type 4
Technical data
Packaging
Order No | |
Multicritical Process Variable indicator Dry Heat, 250 pcs per bag | 504054800 |
Downloads
Relaterede produkter
Getinge GSS67H
A steam sterilizer reducing your utility consumption but boosts your throughput.
Getinge GSS610H
The GSS610H Sterilizer will keep your sterilization department operating at peak performance, maximizing uptime and efficiency.
Getinge GSS67F
Getinge GSS67F performs chemical sterilization using steam and formalin (formaldehyde dissolved in water) – a very safe and well-proven method.
Stericool
A vaporized hydrogen peroxide (H2O2) and plasma sterilizer used for terminal sterilization of heat and moisture sensitive instruments.