Vascular Graft Tunneler Instrumentation

Vascular Graft Tunneler Instrumentation
Innovative, low profile tunneling system
Overblik
Designed to minimize the soft tissue trauma associated with tunneling [1]
The Vascular Graft Tunneling System is designed to create a subcutaneous tunnel for the placement of a vascular graft in both peripheral and AV access applications. While the Tunneler System can be used with a graft that does not feature a Slider Graft Deployment System (GDS), this proprietary tunneling system was designed to be most effective when used in conjunction with a GDS graft. The Tunneler System and its components are made of surgical-grade stainless steel and are designed for multiple reuse when properly maintained.
Features
The Tunneler System comes with 4 Tunneler rod configurations to accommodate both AV loop graft placement and bypass graft placement.
The Tunneler System is designed to interface with the SLIDER GDS and:
- Minimize soft tissue disruption during the tunneling process by matching the tunnel diameter to the graft diameter [1]
- Reduce pre-wetting of the graft [1]
- Reduce complications (Seroma and Pseudoaneurysm) [1]
- Tunneler rod handles are knurled for better gripping and are equipped with a direction tab to increase control in tunnel placement
An assortment of blunt and pointed tips are available
Peer reviewed published data supporting the clinical benefits observed by physicians who have used the Vascular Graft Tunneling System is available upon request [1]

Tunneling tips feature a large grasping area for easier manipulation.

Creates a tighter tunnel to match graft diameter.

Unique thumb tab provides directional control.
Vascular Graft Tunneler Instrumentation
Product | Description | Reference |
AV-1, Vascular graft tunneler rod | 26 cm Length with 50º curve (Stainless Steel) | 26012 |
AV-2, vascular graft tunneler rod | 27 cm Length with 180º curve (Stainless Steel) | 26013 |
PV-1, Vascular graft tunneler rod | 33 cm Length with 12º curve (Stainless Steel) | 26014 |
PV-2, Vascular graft tunneler rod | 58 cm Length with 24º curve (Stainless Steel) | 26015 |
Vascular graft tunneler instrumentation set w/tray | 2 AV Tunnelers, 2 PV Tunnelers, Set of 8 Tips, 2 per size: 6 mm, 7 mm, 8 mm, 10 mm | 26026 |
Vascular graft tunneler instrumentation tray | 26027 |
Vascular Graft Tunneler Rod Tips (4 mm)
Product | Description | Reference |
Vascular graft tunneler tips (4 mm) | Set of 2 | 26018 |
Vascular graft tunneler tips (5 mm) | Set of 2 | 26019 |
Vascular graft tunneler tips (6 mm) | Set of 2 | 26007 |
Vascular graft tunneler tips (7 mm) | Set of 2 | 26008 |
Vascular graft tunneler tips (8 mm) | Set of 2 | 26009 |
Vascular graft tunneler tips (10 mm) | Set of 2 | 26010 |
Set of 8 size vascular graft tunneler tips | 2 per size: 6 mm, 7 mm, 8 mm, 10 mm | 26006 |
Vascular graft tunneler blunt tips (6 mm) | Set of 2 | 26021 |
Vascular graft tunneler blunt tips (7 mm) | Set of 2 | 26022 |
Vascular graft tunneler blunt tips (8 mm) | Set of 2 | 26023 |
Vascular graft tunneler blunt tips (10 mm) | Set of 2 | 26024 |
Relaterede produkter
Alle referencer
-
Schild AF, Baltodano NM, Alfieri K, Livingstone J, Raines JK. New Graft for Low Friction Tunneling in Vascular Access Surgery. J Vasc Access. 2004 Jan-Mar;5(1):19-24.